Basic information
According to your requirements, a manometer with a different range and membrane connection can be supplied (eg CLAMP DIN32676 DN40 - collar 50.5 mm)
- housing material: DIN 1.4301 (AISI 304), mechanism: DIN 1.4301 (AISI 304), connecting thread material and Bourdon springs: DIN 1.4401 (AISI 316).
- the connector is TIG welded
- filling: silicone oil FLUID AK 350 200KG DRUM ST
- dial cover: tempered glass
- range: 0–10 bar
- bottom connection, thread G1 / 2 “BSP
- size of dials: DN 101.5 mm
- operating ambient temperature: –20 ° C to +60 ° C
- medium temperature: max. 100 ° C
- meet the requirements of EN 837-1 / 5, accuracy class CL 1.6%
- protection: IP65
- voltage: 230V DC
- electrical power: 30 VA
- maximum current: 1 A
Technical parameters of the membrane
DIN clamp DN50 (64 mm), connection 1/2"
separating membrane body material | DIN 1.4404 (AISI 316L) |
CLAMP separator material | DIN 1.4401 (AISI 316) |
separation membrane filling | vegetable oil |
pressure | 0-60 bar |
working temperature | -45 °C…150 °C |