Stainless steel manometer with electrical contacts and separating membrane-clamp, dial 100 mm
This type of pressure gauge is used to measure the pressure of liquids and gases in cases where it is inadmissible for the measured medium to enter the measuring device of the pressure gauge. The concept consists in the use of a separating membrane and an inert liquid, which transmits the pressure to the measuring device of the manometer.
Basic information
This type of pressure gauge is used to measure the pressure of liquids and gases in cases where it is inadmissible for the measured medium to enter the measuring device of the pressure gauge. The concept consists in the use of a separating membrane and an inert liquid, which transmits the pressure to the measuring device of the manometer.
The use of these manometers is common in the following cases
- highly viscous liquids
- solid particles, sedimenting sludges
- hot liquids that solidify or crystallize when the temperature drops
- aggressive liquids
- in cases where there are strict requirements for perfect cleaning and sanitation of the system
Technical parameters of the manometer
- housing material: DIN 1.4301 (AISI 304), mechanism: DIN 1.4301 (AISI 304), connecting thread material and Bourdon springs: DIN 1.4401 (AISI 316)
- the connector is TIG welded
- filling: silicone oil FLUID AK 350 200KG DRUM ST
- dial cover: tempered glass
- range: 0–10 bar
- bottom connection, thread G1 / 2 “BSP
- dial size: DN 101.5 mm
- operating ambient temperature: –20 ° C to +60 ° C
- medium temperature: max. 100 °C
- meets the requirements of EN 837-1 / 5, accuracy class CL 1.6%
- protection: IP65
- voltage: 230V DC
- electric power: 30 VA
- maximum current: 1 A
Separating membrane, CLAMP DN50
- DIN clamp DN50 (64 mm), connection 1/2"
- material clamp connection: DIN 1.4401 (AISI 316)
- the material of the body separating membrane: DIN 1.4404 (AISI 316L)
- the material of the CLAMP separator: DIN 1.4401 (AISI 316)
- separation membrane filling: vegetable oil
- pressure: 0-60 bar
- working pressure: -45 °C …150 °C
Installation of the manometer with separating membrane
The connection is made using a clamp sleeve and a silicone seal with a given clamp counterpart (not part of this product - must be ordered).